It is designed for mounting in JA-19xPL multi-purpose boxes or on a DIN rail. The outputs are isolated from the bus. It is set using the DIP switch.
It is not addressable (does not occupy a position in the security system).
Power supply | via the control panel bus 12 V (9 ... 15 V) |
---|---|
Current consumption during backup open/closed outputs | 5 mA/10m A |
Current consumption for cable selection | 10 mA |
Maximum current from an output +U (electronic fuse) | <100 mA (all connected devices must be added for current calculations) |
Dimensions | 77 x 40 x 15 mm |
Classification | level 2 in acc. with EN 50131-1, only when module is located in a JA-194PL or JA-195PL box using the JA-111H TRB module |
Environment according to | EN 50131-1 II. general indoor |
Operation temperature range | -10 °C to +40 °C |
It also meets the requirements of | EN 50131-3, EN 50130-4 ed. 2+A1, EN 55032, EN 50581 |