Jablotron

JA-116H BUS expander – 16 inputs

Bus expander is used for powering and connecting up to 16 detectors with contact outputs. It is possible to install the module straight into the JA-106K control panel.

BUS expander – 16 inputs

JA-116H BUS expander – 16 inputs

Technical specifications

Power 12 V (9 … 15 V)
Current consumption (all outputs turned on) 25 mA
Caution: the consumptions of the detectors connected to the +U and GND terminals have to be added to the system power backup calculation.
Maximum acceptable load of one output from +U and GND 100mA
Maximum acceptable load of all outputs from +U GND 4 x 100mA
Dimensions 102 x 66 x 20 mm
Classification Grade II
according to EN 50131-1, EN 50131-3
Operational environment according to EN 50131-1 II. Indoor general
Operating temperature range -10 to +40 °C
Also complies with EN 50130-4, EN 55022

Related products

JA-111H TRB Bus module interface for wire detector

The JA-111H TRB module is designed for the connection of any wired detector (with contact or impulse outputs) to the JABLOTRON 100+ system and provides it with a power supply.

JA-111H-AD TRB Bus module for system control

The JA-111H-AD TRB is designed for the connection of any control device (with contact or impulse outputs) to the JABLOTRON 100+ system and provides it with a power supply from the control panel bus.